상세 보기
EQS 면진장치의 항복 후 강성을 고려한 면진 원전구조물의 지진응답
- 김병수;
- 송종걸
초록
The Eradi Quake System (EQS) is a seismic isolation bearing system designed to minimize forces and displacements experienced by structures subjected to ground motion. The EQS dissipates seismic energy through friction of Poly Tetra Fluoro Ethylene (PTFE) disk pad. In general, a force-displacement relationship of EQS has post yield stiffness hardening during large inelastic displacement. In this study, seismic responses of seismically isolated nuclear power plant (NPP) subjected to design basis earthquake (DBE) and beyond design basis earthquakes (150% DBE and 167% DBE) are compared considering the post yield stiffness hardening effect of EQS. From the results, it can be observed that if the post-yield stiffness hardening effect of EQS is increased, the displacement response of EQS is reduced, and the acceleration and shear responses of containment structures of NPP is increased.
키워드
- 제목
- EQS 면진장치의 항복 후 강성을 고려한 면진 원전구조물의 지진응답
- 제목 (타언어)
- Seismic Responses of Seismically Isolated Nuclear Power Plant Structure Considering Post-Yield Stiffness of EQS Bearing
- 저자
- 김병수; 송종걸
- 발행일
- 2016-09
- 유형
- Y
- 저널명
- 한국지진공학회논문집
- 권
- 20
- 호
- 5
- 페이지
- 319 ~ 329