초록
A stereospecific HPLC method has been developed for the resolution of the enantiomers of salbutamol in human urine. After solid-phase extraction and derivatization with 2,3,4,6-tetra-O-acetyl-β-D-glucopyranosyl isothiocyanate, the diastereomeric derivatives were resolved (Rs=1. 83) on 5 μm octadecylsilan column using 35% acetonitrile in 0.05M ammonium acetate buffer (pH=6) as a mobile phase with electrochemical detection. The diastereomeric derivatives were formed within 30 min. The detection limit of each enantiomer was 20 ng/ml (S/N=3).
키워드
2,3, 4,6-Tetra-o-acetyl-β-d-glucopyranosyl isothiocyanate; Chiral derivatizing reagent; Chiral separation; Enantiomer; HPLC; Salbutamol
- 제목
- Resolution of salbutamol enantiomers in human urine by reversed-phase high performance liquid chromatography after derivatization with 2,3,4,6-tetra-O-acetyl-β-D-glucopyranosyl isothiocyanate
- 저자
- Kim, Kyeong-ho; Kim, Tae-kyun
- 발행일
- 1998
- 유형
- Article
- 권
- 21
- 호
- 2
- 페이지
- 217 ~ 222