Shielding design of radiation areas requires comprehensive consideration of the environment. However, the current situation is that the thickness of shielding materials is conservatively designed to reduce risk factors, and thickness standards are basically calculated using a formula to estimate the shielding before design. This research proposes a hybrid method for optimal shielding thickness that combines simulation and actual data. Dose conversion factor (DCF) calculated in 1.5 mm lead situation, compared with MCNP and Actual dosimeters (PED, CD-Gam-1), and the lead shielding design of the five types from 0.25 mm lead to 1.25 mm lead was simulated with a 0.25 mm lead interval, and evaluation areas was divided into radiation workers (< 20 mSv/yr) and patients (< 1 mSv/yr) in detail. When applying PED-DCF and CD-Gam-1-DCF, the result was a lead thickness reduction of up to 1.25 mm lead. Therefore, we propose a radiation protection facility inspection method designed in hybrid.

키워드

Radiation inspection; Shielding design; Monte Carlo simulation; General X-ray; Dosimeter; Radiation protection
제목
Proposal of Hybrid Shielding Method focused on General X-ray Facility Inspection
저자
Ji, Young-Seok; Kim, Jo-Ho; Han, Man-Seok
DOI
10.4283/JMAG.2023.28.4.449
발행일
2023-12
유형
Article
저널명
Journal of Magnetics
권
28
호
4
페이지
449 ~ 455