Impact of pannus formation on hemodynamic dysfunction of prosthetic aortic valve: pannus extent and its relationship to prosthetic valve motion and degree of stenosis

  • Koo, Hyun Jung; 
  • Ha, Hojin; 
  • Kang, Joon-Won; 
  • Kim, Jeong A.; 
  • Song, Jae-Kwan; 
  • 외 3명
Citations

WEB OF SCIENCE

8
Citations

SCOPUS

15

초록

Background Although pannus is an important cause of prosthetic valve dysfunction, the minimum pannus size that can induce hemodynamic dysfunction has not yet been determined. This study investigated the correlation between the limitation of motion (LOM) of the prosthetic valve and pannus extent and determined the pannus extent that could induce severe aortic stenosis. Methods This study included 49 patients who underwent mechanical aortic valve replacement (AVR) and showed pannus on cardiac computed tomography (CT). Pannus width, ratio of pannus width to valve diameter, pannus area, effective orifice area, encroachment ratio by pannus, pannus involvement angle and percent LOM of mechanical valves were evaluated on CT. Transvalvular peak velocity (TPV) and transvalvular pressure gradient (TPG) were measured by transesophageal echocardiography to determine the degree of aortic stenosis. The relationship between percent LOM of the prosthetic valve and pannus extent and the cut-off of pannus extent required to induce severe aortic stenosis were evaluated. Results The mean interval between AVR and pannus formation was 11 years and was longer in patients with than without severe aortic stenosis (14.0 vs. 7.3 years). On CT, the percent LOM of the prosthetic valve was significantly associated with the extent of pannus only in patients with pannus involvement angle > 180 degrees (r = 0.55-0.68, P < 0.01). Pannus width, effective orifice area, and encroachment ratio were significantly associated with increased TPV and TPG (r = 0.51-0.62, P < 0.01). Pannus width > 3.5 mm, pannus width/valve inner diameter > 0.15, and encroachment ratio > 0.14 were significantly associated with severe aortic stenosis (TPV > 4 m/s; mean TPG >= 35 mmHg), with c- indices of 0.74-079 (P < 0.005). Conclusion CT-derived pannus extent parameters are good indicators of significant hemodynamic changes with increased TPV and mean TPG.

키워드

Pannus; Aortic valve replacement; Mechanical valve; Computed tomography; 3-DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY; ROW COMPUTED-TOMOGRAPHY; SUBPROSTHETIC PANNUS; SUBVALVULAR PANNUS; REPLACEMENT; OBSTRUCTION; TRANSCATHETER; DIAGNOSIS; TRENDS
제목
Impact of pannus formation on hemodynamic dysfunction of prosthetic aortic valve: pannus extent and its relationship to prosthetic valve motion and degree of stenosis
저자
Koo, Hyun Jung; Ha, Hojin; Kang, Joon-Won; Kim, Jeong A.; Song, Jae-Kwan; Kim, Hwa Jung; Lim, Tae-Hwan; Yang, Dong Hyun
DOI
10.1007/s00392-018-1217-3
발행일
2018-07
유형
Article
저널명
Clinical Research in Cardiology
권
107
호
7
페이지
554 ~ 564