상세 보기
Rolling Mill Cycloconverter Condition Assessment by Harmonic Current via Time-Frequency Signature
- Thompkins, Timothy Mitchell;
- Kim, Do-In;
- Stone, Philip;
- Shin, Yong-June
WEB OF SCIENCE
4SCOPUS
6초록
High-power industrial rolling mills rely heavily on the sustained operation of cycloconverters, a type of variable-frequency drive. This research proposes a methodology, which observes and diagnoses the operation of cycloconverters as either normal or abnormal by use of time-frequency signature analysis. Various features of the cycloconverter's input current in the time-frequency domain are identified and used to derive parameters that describe these two states in a quantitative manner. A reference model using the parameters is then developed, and comparisons in the time-frequency domain to real data are implemented. Based on these comparisons, a statistical decision boundary is delineated that is used to classify the health status of the cycloconverter.
키워드
- 제목
- Rolling Mill Cycloconverter Condition Assessment by Harmonic Current via Time-Frequency Signature
- 저자
- Thompkins, Timothy Mitchell; Kim, Do-In; Stone, Philip; Shin, Yong-June
- 발행일
- 2018-10
- 유형
- Article
- 권
- 14
- 호
- 10
- 페이지
- 4376 ~ 4384
- 언어
- ENG
- 출판사
- IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
- 발행국가
- 미국
- 분량
- 9 페이지
- ISSN
- E 1941-0050
P 1551-3203