Effects of SF6 on the avalanche mode operation of a real-sized double-gap resistive plate chamber for the Compact Muon Solenoid experiment

  • Ahn, SH
  • Hong, B
  • Hong, SJ
  • Ito, M
  • Kang, TI
  • 외 19명
Citations

WEB OF SCIENCE

6
Citations

SCOPUS

8

초록

We present the design and the test results for a real-sized prototype resistive plate chamber by using cosmic-ray muons for the forward region of the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC). In particular, we investigate the effects of adding SF6 to the gas mixture for the avalanche inode operation of a resistive plate chamber. A small fraction of SF6 is very effective in Suppressing streamer signals in a resistive plate chamber. The shapes of the muon detection efficiency and the muon cluster size remain similar, but are shifted to higher operating voltage by SF6. The noise cluster rate and size are not influenced by SF6.

키워드

real-size RPCCMSLHCSF6avalanche modeCMS/LHC EXPERIMENTENDCAP REGIONRPCPERFORMANCECMSDETECTORENVIRONMENTDEPENDENCESIMULATIONBAKELITE
제목
Effects of SF6 on the avalanche mode operation of a real-sized double-gap resistive plate chamber for the Compact Muon Solenoid experiment
저자
Ahn, SHHong, BHong, SJIto, MKang, TIKim, BIKim, JHLee, HWLee, KBLee, KSLim, JKMoon, DHPark, SPark, WJRyu, ASShim, HHSim, KSBahk, SYKim, YJKim, YUKoo, DGLee, SJNam, SKRhee, JT
발행일
2005-05
유형
Article
저널명
Journal of the Korean Physical Society
46
5
페이지
1090 ~ 1095