초록
This study is to validate the K University daylight measurement system according to the CIE guide of recommended practice of daylight measurement. In this study global irradiance, illuminance, direct normal illuminance, diffuse irradiance, illuminance and vertical illuminances(North, West, South, East) were measured and compared in accordance with the CIE quality control test. Field monitoring was conducted from 1st August to 15th August 2010. Results for the CIE tests 1 to 4 showed an accuracy of 100%. This indicates that the K University daylight measurement system is reliable and the measurement data would be useful for further daylight researches.
키워드
자연채광 측정시스템; 조도; 일사량; CIE; 주광; Daylight Masurement System; Illuminance; Irradiance; CIE; Daylight; Daylight Masurement System; Illuminance; Irradiance; CIE; Daylight
- 제목
- CIE 권장가이드를 이용한 자연채광 기후요소 측정시스템의 유효성 검증
- 제목 (타언어)
- Validation of a Daylight Measurement System Using the CIE Guide of Recommended Practice of Daylight Measurement
- 저자
- 공효주; 이종수; 김곤; 윤근영; 김정태
- 발행일
- 2010-12
- 유형
- Y
- 저널명
- KIEAE Journal
- 권
- 10
- 호
- 6
- 페이지
- 41 ~ 46