Development of submercible axial pump for wastewater

Citations

SCOPUS

3

초록

This study was performed to develop a high efficiency submersible axial pump for concentration wastewater treatment. To do this, we simulated the effect of some parameters such as the axial twist angle of a blade(β), the radial twist angle of a blade(α) and the length of a blade on pump cfficicncy using commercial code, ANSYS CFX and BladeGen. The results showed that the axial twist angle of a blade(/J) was the most sensible parameter on the pump cfficicncy. And the pump cfficicncy had a maximum at β =20°, α-110° and =240 mm. © 2013 The Korean Society of Mechanical Engineers.

키워드

Axial pumpBlade lengthenBlade shapeWastewater pump
제목
Development of submercible axial pump for wastewater
저자
Yun, Jeongeui
DOI
10.3795/KSME-B.2013.37.2.149
발행일
2013
유형
Article
저널명
대한기계학회논문집 B
37
2
페이지
149 ~ 154