초록
This study was performed to develop a high efficiency submersible axial pump for concentration wastewater treatment. To do this, we simulated the effect of some parameters such as the axial twist angle of a blade(β), the radial twist angle of a blade(α) and the length of a blade on pump cfficicncy using commercial code, ANSYS CFX and BladeGen. The results showed that the axial twist angle of a blade(/J) was the most sensible parameter on the pump cfficicncy. And the pump cfficicncy had a maximum at β =20°, α-110° and =240 mm. © 2013 The Korean Society of Mechanical Engineers.
키워드
Axial pump; Blade lengthen; Blade shape; Wastewater pump
- 제목
- Development of submercible axial pump for wastewater
- 저자
- Yun, Jeongeui
- 발행일
- 2013
- 유형
- Article
- 저널명
- 대한기계학회논문집 B
- 권
- 37
- 호
- 2
- 페이지
- 149 ~ 154