Velocity dispersion and backscatter in marrow-filled and water-filled trabecular bone samples in vitro
Citations
WEB OF SCIENCE
4Citations
SCOPUS
5초록
The phase velocity and the backscatter coefficient were measured in 28 bovine femoral trabecular bone samples filled with marrow and water in vitro from 0.2 to 0.6MHz. The phase velocities decreased approximately linearly with increasing frequency and the average dispersion rate of -34 ms(-1) MHz(-1) in the marrow-filled samples was higher than that of -42 ms(-1) MHz(-1) in the water-filled samples. The backscatter coefficients exhibited nonlinear, monotonically increasing dependences on the frequency and the average value of the exponent n = 2.92 (frequency dependence) in the marrow-filled samples was higher than the value of n = 2.79 in the water-filled samples. (C) 2018 Acoustical Society of America
키워드
CANCELLOUS-BONE; PHASE-VELOCITY; FREQUENCY-DEPENDENCE; ULTRASONIC BACKSCATTER; ATTENUATION; SCATTERING; MODEL
- 제목
- Velocity dispersion and backscatter in marrow-filled and water-filled trabecular bone samples in vitro
- 저자
- Lee, Kang Il
- 발행일
- 2018-11
- 유형
- Article
- 권
- 144
- 호
- 5
- 페이지
- EL386 ~ EL391
- 언어
- ENG
- 출판사
- ACOUSTICAL SOC AMER AMER INST PHYSICS
- 발행국가
- 미국
- ISSN
- E 1520-8524
P 0001-4966