The present study reports on the speech intelligibility as measured by speech transmission index (STI) and useful-to-detrimental sound ratios (U-50) in university classrooms. Acoustic measurements were made in 12 quietly occupied university classrooms. The measured impulse responses of the classrooms were used to determine the modulation transfer function, m(F), for the STI calculation according to IEC 60268-16. U-50 values were determined from both signal-to-noise ratios (SNR) and C-50 values. The mean STI and frequency-weighted U-50 values for the 12 occupied classrooms were strongly linearly related. The results showed that classrooms with U-50 values of about +0.5 dB correspond to STI values of 0.60, indicating 'good' acoustical conditions for speech intelligibility. The results illustrate that the U-50 measure can be a more practically useful means of assessing and understanding room acoustics conditions for real speech communication in active classrooms.