상세 보기
Protocol Optimization of Coronary CT Angiography
- 이해각;
- 유흥준;
- 이선엽;
- 구은회;
- 석종민;
- ... 한만석;
- 외 4명
초록
This research compared and analyzed the heart rate of the patient in which the LVEF value is 40% less than and normal patient. When as for LVEF 40% or less becomes to each heart rate and LVEF in a relation, we can know that the time to reach 100HU hangs long. Therefore, in patients, that is 40% less than, when setting up the Premonitoring delay, we could know to could give 5 primary solid phrases. It is seen that subsequently an addition injected 40cc as to Saline, to all patients by 4cc/sec speeds after injecting the capacity of Scan time x 4cc + 30cc with 4cc/sec speeds. And HR excludes 80 or greater in 40% less than, the contrast agent shows the large-scale difference. In addition, in 40% less than, it could predict that the time difference was big and the contrast agent was already out in the Left ventricle Wash- when the contrast agent reached 100HU and Scan was started There is a wide difference between under 40% LVEF and normal. when starting scan from low LVEF patients. So, Injection contrast media protocol Should be determined to CCTA . And then In case of low LVEF is recommended to more low Pitch than routine Pitch because we should reduce scan failed in accordance with low LVEF.
키워드
- 제목
- Protocol Optimization of Coronary CT Angiography
- 제목 (타언어)
- 심혈관 CT 조영술의 프로토콜 최적화
- 저자
- 이해각; 유흥준; 이선엽; 구은회; 석종민; 한만석; 이광성; 조재환; 김보희; 박철수
- 발행일
- 2011-04
- 유형
- Y
- 저널명
- 한국방사선학회논문지
- 권
- 5
- 호
- 2
- 페이지
- 51 ~ 58