Shear failure analysis of concrete beams reinforced with newly developed GFRP stirrups

Citations

WEB OF SCIENCE

0

초록

Even though the application of fiber reinforced polymer (FRP) as a concrete reinforcement becomes more common with various advantages, one of the inherent shortcomings may include its brittleness and on-site fabrication and handling. Therefore, the shape of FRP products have been limited only to a straight bar or sheet type. This study suggests a new technique to use glass fiber reinforced polymer (GFRP) bars for the shear reinforcement in concrete beams, and investigates its applicability. The developed GFRP stirrup was used in the concrete instead of ordinary steel stirrups. The experimental program herein evaluates the effectiveness of the GFRP stirrups with respect to different shear reinforcing ratios under three different shear span-to-depth testing schemes. At the same shear reinforcing ratio, the ultimate loads of the beams were similar regardless the shear reinforcing materials. Once a major crack occurs in concrete, however, the failure modes seemed to be relatively brittle with GFRP stirrups. From the measured strains on the surface of concrete, the shear stresses sustained by the stirrups were calculated and the efficiency of the GFRP stirrups was shown to be 91% to 106% depending on the shear span-to-depth ratio.

키워드

newly developed GFRP stirrupshear failureshear reinforcement ratioshear span-to depth ratio
제목
Shear failure analysis of concrete beams reinforced with newly developed GFRP stirrups
저자
Park, CheolwooSim, Jongsung
DOI
10.4028/www.scientific.net/KEM.324-325.995
발행일
2006
유형
Proceedings Paper
저널명
Key Engineering Materials
324-325
페이지
995 ~ +