This study investigates the lateral resistance of micro-pile system when surcharge load is acting on the back of retaining wall. Both laboratory experiments and numerical analysis were performed. The experimental retaining wall model was developed on the laboratory-sized foundation. While surcharge load was acting, the interval and length varied as experimental variables. From the investigation it is known that the micro-pile system can effectively control the lateral displacement which is developed on the precast retaining wall. The effectiveness became increased as the pile interval reduced and the length of pile increased. The greatest reinforcing efficiency was shown when the pile length was 0.5H and the interval was 7D.
키워드
- 제목
- 프리캐스트 옹벽 마이크로 파일의 보강 효율
- 제목 (타언어)
- Reinforcing Efficiency of Micro-Pile with Precast Retaining Wall
- 저자
- 문창열
- 발행일
- 2008-12
- 유형
- Y
- 저널명
- 한국지반환경공학회 논문집
- 권
- 9
- 호
- 7
- 페이지
- 61 ~ 71