리플전압을 이용한 병렬아크 사고 감지기 개발

Development of Parallel Arc Fault Detector Using Ripple Voltage

초록

The major causes of electrical fire in low-voltage distribution lines are classified into short-circuit fault, overload fault, electric leakage, and electric contact failure. The special principal factor of the fire is electric arc or spark accompanied with such electric faults. This paper studies the development of an electric fire prevention system with detection and alarm of that in case of parallel arc fault occurrence in low-voltage distribution lines. The proposed system is designed on algorithm sensing the instantaneous voltage drop of line voltage at arc fault occurrence. The proposed detector has characteristics of high-speed operation responsibility and superior system reliability from composition using a large number of semiconductor devices. A new sensing control method that shows the detection of parallel arc fault is sensed to ripple voltage drop through a diode bridge full-wave rectifier at electrical accident occurrence. Some experimental tests of the proposed system also confirm the practicality and validity of the analytical results.

키워드

Electric fireParallel arc faultRipple voltageShort circuit faultVoltage drop
제목
리플전압을 이용한 병렬아크 사고 감지기 개발
제목 (타언어)
Development of Parallel Arc Fault Detector Using Ripple Voltage
저자
최정규곽동걸
DOI
10.6113/TKPE.2016.21.5.453
발행일
2016-10
유형
Y
저널명
전력전자학회 논문지
21
5
페이지
453 ~ 456