초록
The yield shear strength of bolt connection in glass fiber reinforced glulam was predicted using a design-based equation, and was compared to the empirical yield shear strength. For the predicted equation, the mechanical properties of member (the elastic modulus, Poisson's ratio, shear modulus) was tested. The fracture toughness factor (Kft) of glass fiber reinforced glulam was reflected to the revision of the design equation of bolted connection. The compressive strength properties to grain direction was influenced by annual ring angle and width of lamina. Compared with the revised yield shear strength of reinforced glulam, it was tended to be similar to the empirical yield shear strength on the diameter of bolt and the reinforcements. The revised yield shear strength from proposed formula of KBC was most appropriately matched in the bolt connection of the glass fiber reinforced glulam.
키워드
- 제목
- Estimate of bolt connection strength of reinforced glulam using glass fiber
- 저자
- Kim, Keonho; Hong, Soonil
- 발행일
- 2016
- 유형
- Article
- 저널명
- 목재공학
- 권
- 44
- 호
- 1
- 페이지
- 67 ~ 74