Effects of substrate concentrations on performance of serially connected microbial fuel cells (MFCs) operated in a continuous mode

  • Gurung, Anup
  • Kim, Jungrae
  • Jung, Sokhee
  • Jeon, Byong-Hun
  • Yang, Jae E.
  • ... Oh, Sang-Eun
Citations

WEB OF SCIENCE

40
Citations

SCOPUS

45

초록

Stacking of microbial fuel cells (MFC) by connecting multiple small-sized units in a series is used for generating higher power from the MFCs. However, voltage reversal is a critical problem in a serially connected MFC unit. The voltage reversal often occurs when substrate concentration is relatively low in the anodic compartment. Two rectangular individual cells were stacked together in series: MFC1 was fed with 1 g glucose L-1 throughout the experiment while MFC2 was fed with various concentrations of glucose (0.1, 0.2, 0.3, 0.5 and 0.8 g L-1). Voltage reversal occurred when the stack configuration was performed using (1 + 0.1) g glucose L-1. The stacked configurations with (1 + 0.2, 1 + 0.3, 1 + 0.5 and 1 + 0.8) g glucose L-1 were operated successfully without the voltage reversal. The maximum powers of 1.88, 2.04, 3.6, 2.5 and 2.18 mW were obtained with the stacked configurations of (1 + 0.2), (1 + 0.3), (1 + 0.5), (1 + 0.8) and (1 + 1) g glucose L-1, respectively. Except in the stacked configuration with (1 + 0.1) g glucose L-1, the stacked voltages obtained were similar.

키워드

ElectricityHydraulicallyMicrobial fuel cellStackingELECTRICITY-GENERATIONEXCHANGE MEMBRANESTACKCONFIGURATIONTECHNOLOGYCATHODE
제목
Effects of substrate concentrations on performance of serially connected microbial fuel cells (MFCs) operated in a continuous mode
저자
Gurung, AnupKim, JungraeJung, SokheeJeon, Byong-HunYang, Jae E.Oh, Sang-Eun
DOI
10.1007/s10529-012-0979-3
발행일
2012-10
유형
Article
저널명
Biotechnology Letters
34
10
페이지
1833 ~ 1839