Hemodynamic Measurement Using Four-Dimensional Phase-Contrast MRI: Quantification of Hemodynamic Parameters and Clinical Applications

  • Ha, Hojin
  • Kim, Guk Bae
  • Kweon, Jihoon
  • Lee, Sang Joon
  • Kim, Young-Hak
  • 외 3명
Citations

WEB OF SCIENCE

37
Citations

SCOPUS

45

초록

Recent improvements have been made to the use of time-resolved, three-dimensional phase-contrast (PC) magnetic resonance imaging (MRI), which is also named four-dimensional (4D) PC-MRI or 4D flow MRI, in the investigation of spatial and temporal variations in hemodynamic features in cardiovascular blood flow. The present article reviews the principle and analytical procedures of 4D PC-MRI. Various fluid dynamic biomarkers for possible clinical usage are also described, including wall shear stress, turbulent kinetic energy, and relative pressure. Lastly, this article provides an overview of the clinical applications of 4D PC-MRI in various cardiovascular regions.

키워드

4D phase-contrast MRI4D flow MRIBlood flowHemodynamicsWALL SHEAR-STRESSCARDIOVASCULAR MAGNETIC-RESONANCESENSITIVE 4D MRIBICUSPID AORTIC-VALVEPULSE-WAVE VELOCITYTURBULENT KINETIC-ENERGYBLOOD-FLOWCAROTID-ARTERYINTRACRANIAL ANEURYSMSPC-MRI
제목
Hemodynamic Measurement Using Four-Dimensional Phase-Contrast MRI: Quantification of Hemodynamic Parameters and Clinical Applications
저자
Ha, HojinKim, Guk BaeKweon, JihoonLee, Sang JoonKim, Young-HakLee, Deok HeeYang, Dong HyunKim, Namkug
DOI
10.3348/kjr.2016.17.4.445
발행일
2016-07
유형
Review
저널명
Korean Journal of Radiology
17
4
페이지
445 ~ 462