상세 보기
Measurement of the speed of sound in trabecular bone by using a time reversal acoustics focusing system
- Lee, Kang Il;
- Choi, Bok Kyoung
WEB OF SCIENCE
0SCOPUS
0초록
A new method for measuring the speed of sound (SOS) in trabecular bone by using a time reversal acoustics (TRA) focusing system was proposed and validated with measurements obtained by using the conventional pulse-transmission technique. The SOS measured in 14 bovine femoral trabecular bone samples by using the two methods was highly correlated each other, although the SOS measured by using the TRA focusing system was slightly lower by an average of 2.2 m/s. The SOS measured by using the two methods showed high correlation coefficients of r = 0.92 with the apparent bone density, consistent with the behavior in human trabecular bone in vitro. These results prove the efficacy of the new method based on the principle of TRA to measure the SOS in trabecular bone.
키워드
- 제목
- Measurement of the speed of sound in trabecular bone by using a time reversal acoustics focusing system
- 저자
- Lee, Kang Il; Choi, Bok Kyoung
- 발행일
- 2014-10
- 유형
- Article
- 권
- 65
- 호
- 7
- 페이지
- 1036 ~ 1039