Multiple factors influence the morphology of the bipolar electrogram: An in silico modeling study

  • Hwang, Minki; 
  • Kim, Jaehyuk; 
  • Lim, Byounghyun; 
  • Song, Jun-Seop; 
  • Joung, Boyoung; 
  • ... Shim, Eun Bo; 
  • 외 1명
Citations

WEB OF SCIENCE

26
Citations

SCOPUS

31

초록

Although bipolar electrograms (Bi-egms) are commonly used for catheter mapping and ablation of cardiac arrhythmias, the accuracy and reproducibility of Bi-egms have not been evaluated. We aimed to clarify the influence of the catheter orientation (CO), catheter contact angle (CA), local conduction velocity (CV), scar size, and catheter type on the Bi-egm morphology using an in silico 3-dimensional realistic model of atrial fibrillation. We constructed a 3-dimensional, realistic, in silico left atrial model with activation wave propagation including bipolar catheter models. Bi-egms were obtained by computing the extracellular potentials from the distal and proximal electrodes. The amplitude and width were measured on virtual Bi-egms obtained under different conditions created by changing the CO according to the wave direction, catheter-atrial wall CA, local CV, size of the non-conductive area, and catheter type. Bipolar voltages were also compared between virtual and clinically acquired Bi-egms. Bi-egm amplitudes were lower for a perpendicular than parallel CO relative to the wave direction (p<0.001), lower for a 90 degrees than 0 degrees CA (p<0.001), and lower for a CV of 0.13m/s than 0.48m/s (p<0.001). Larger sized non-conductive areas were associated with a decreased bipolar amplitude (p<0.001) and increased bipolar width (p<0.001). Among three commercially available catheters (Orion, Pentaray, and Thermocool), those with more narrowly spaced and smaller electrodes produced higher voltages on the virtual Bi-egms (p<0.001). Multiple factors including the CO, CA, CV, and catheter design significantly influence the Bi-egm morphology. Universal voltage cut-off values may not be appropriate for bipolar voltage-guided substrate mapping. Author summary Cardiac arrhythmias are rhythm disorders of the heart leading to abnormal heart function. For the diagnosis and treatment of the arrhythmias, clinicians insert catheters into the heart and examine the electrical signal propagation in the heart. Among different type of catheters, bipolar catheters have two electrodes at the tip of the catheter with the signal being the difference between the two electrodes, which provides sharper signal than unipolar catheter. However, bipolar electrogram is dependent on many factors including catheter design and orientation, and consequently, knowledge of the determinants of the bipolar electrogram is needed for proper interpretation of the signal. In this study, we examined the effects of many factors on bipolar electrogram using computer simulation. Computer simulation is very useful in this type of study because, in clinical settings, it is not feasible to control each factor precisely. We quantitatively demonstrated the effects of catheter design and orientation, and cardiac wave propagation speed on bipolar electrogram.

키워드

VEIN ANTRUM ISOLATION; ATRIAL-FIBRILLATION; MAGNETIC-RESONANCE; VOLTAGE; SCAR; QUANTIFICATION; ABLATION
제목
Multiple factors influence the morphology of the bipolar electrogram: An in silico modeling study
저자
Hwang, Minki; Kim, Jaehyuk; Lim, Byounghyun; Song, Jun-Seop; Joung, Boyoung; Shim, Eun Bo; Pak, Hui-Nam
DOI
10.1371/journal.pcbi.1006765
발행일
2019-04
유형
Article
저널명
PLoS Computational Biology
권
15
호
4