Ultrasonic properties in marrow-filled and water-filled bovine femoral trabecular bones in vitro

Citations

WEB OF SCIENCE

2
Citations

SCOPUS

4

초록

Phase velocity and normalized broadband ultrasound attenuation (nBUA) were measured in 22 marrow-filled and water-filled bovine femoral trabecular bone samples. Replacement of marrow by water led to a significant increase in the mean phase velocity of 47 +/- 12 m/s (+3.1%), but a decrease in the mean nBUA of 10.4 +/- 2.9 dB/cm/MHz (-38.9%). All the ultrasonic properties in the marrow-filled and water-filled samples exhibited significant negative Pearson's correlation coefficients of r = -0.87 to -0.92 with porosity. High correlations were also observed between pairs of the ultrasonic properties, with r = 0.85 to 0.93. (C) 2012 Acoustical Society of America

키워드

HUMAN CALCANEUSCANCELLOUS BONEELASTIC WAVESFREQUENCYPROPAGATIONVELOCITYFLUIDBIOT
제목
Ultrasonic properties in marrow-filled and water-filled bovine femoral trabecular bones in vitro
저자
Lee, Kang Il
DOI
10.1121/1.4751989
발행일
2012-10
유형
Article
저널명
Journal of the Acoustical Society of America
132
4
페이지
EL296 ~ EL302