상세 보기
Histomorphometric Analysis of Contaminated Autogenous Tooth Graft Materials After Various Sterilization
- Jin, Soo-Young;
- Kim, Su-Gwan;
- Oh, Ji-Su;
- You, Jae-Seek;
- Lim, Sung-Chul;
- ... Jeong, Mi-Ae;
- 외 1명
WEB OF SCIENCE
6SCOPUS
6초록
Purpose: The purpose of this study was to evaluate histomorphometrically contaminated autogenous tooth graft materials, which were resterilized. Materials and Methods: The intentional defects (diameter: 8 mm, depth: 4 mm) were formed around implant fixture on the iliac crest of 6 mongrel dogs. Autogenous tooth graft materials were made by extracted premolars. After the contamination of the tooth materials, graft procedure was performed; no contaminated group (control group), contaminated groups (nonsterilization group [group 1], ethylene oxide [EO] gas group [group 2], and autoclave group [group 3]). The bone-to-implant contact (BIC) and the new bone formation rate (NBFR) were evaluated after sacrifice. Results: The BIC and NBFR of groups 1 and 3 were significantly lower than the control group after 4 weeks. The BIC and NBRF of group 3 were significantly lower than the control group after 8 weeks. However, the BIC and NBRF of group 2 was not significantly different comparing with the control group after 4 and 8 weeks. Conclusion: Sterilization using EO gas may be more favorable than high-pressure sterilization in cases the reuse of contaminated autogenous tooth graft materials.
키워드
- 제목
- Histomorphometric Analysis of Contaminated Autogenous Tooth Graft Materials After Various Sterilization
- 저자
- Jin, Soo-Young; Kim, Su-Gwan; Oh, Ji-Su; You, Jae-Seek; Lim, Sung-Chul; Jeong, Mi-Ae; Kim, Jin-Son
- 발행일
- 2016-02
- 유형
- Article
- 권
- 25
- 호
- 1
- 페이지
- 83 ~ 89