A comparison study of fire resistance of high strength structural steels according to boundary condition

  • Kwon, Ill-kyong
Citations

SCOPUS

0

초록

Material strength is one of the most important factors in designing a building. For this reason, many structural steel manufacturers have been trying to develop it. In Korea, SM 570 is one high structural steel that has many merits such as longer span and reduction of construction cost for steel works. However, the fire resistance performance of H-section made of SM 570 has not been evaluated. Especially, in high-rise steel building that can be built with various joint systems like hinged to hinge, hinge to fixed, and fixed to fixed. However, the performance of fire resistant is limited. In this paper, to evaluate the fire resistance of H-section made of SM 570, the advanced fire design was conducted using regressive equation of the mechanical and thermal properties at high temperature, compared with those made of an ordinary structural steel, SS 400. The facts show that hinge to hinge had the lowest load bearing capacity at high temperature. Therefore, to keep the same fire resistance with other types boundary conditions, the more passive fire materials are required. © (2014) Trans Tech Publications, Switzerland.

키워드

Boundary conditionFire designFire performanceHigh strength structural steelsMechanical properties at high temperature
제목
A comparison study of fire resistance of high strength structural steels according to boundary condition
저자
Kwon, Ill-kyong
DOI
10.4028/www.scientific.net/AMR.901.11
발행일
2014
유형
Conference paper
저널명
Advanced Materials Research
901
페이지