Heat transfer performance of loop heat pipe for space vehicle thermal control under bypass line operation

Citations

WEB OF SCIENCE

18
Citations

SCOPUS

21

초록

This study analyzed the experimental results regarding the heat transfer performance of a loop heat pipe (LHP) with a vapor bypass line and a polypropylene fiber capillary wick. The LHP with the bypass tube between the vapor channel and liquid chamber was fabricated, tested, and analyzed. A control valve was attached to the inlet of the bypass line to manually switch between the bypass line operating mode and the normal operating mode. The polypropylene capillary wick generated the capillary pressure to operate the LHP. The container and tubing system of the LHP were of stainless steel, and methanol was used as the working fluid. The planar dimensions of the LHP with a flat evaporator were 40 mm x 50 mm. The study investigated the effect of the auxiliary loop on the LHP. The effects of the bypass line were investigated in terms of the minimum start-up thermal load, start-up thermal performance, and steadystate performance. The minimum start-up thermal load of the LHP was reduced by up to 63% under the bypass line operation compared with the normal operation. The temperature overshoot in the evaporator outer wall was eliminated during the start-up under the bypass line operation. Furthermore, the steadystate heat transfer performance was favorably enhanced at high thermal loads under the bypass line operation.(c) 2022 Elsevier Ltd. All rights reserved.

키워드

Loop heat pipeFlat evaporatorTemperature overshootBypass linePolypropylene fiber wickStart-upMENISCUS TYPE EVAPORATORFIBER SINTERED SHEETWICK
제목
Heat transfer performance of loop heat pipe for space vehicle thermal control under bypass line operation
저자
Baek, YongmiJung, Eui Guk
DOI
10.1016/j.ijheatmasstransfer.2022.123064
발행일
2022-09-15
유형
Article
저널명
International Journal of Heat and Mass Transfer
194