Optimized pleat geometry at specific pleat height in pleated filters for air purification

Citations

WEB OF SCIENCE

13
Citations

SCOPUS

13

초록

The performance of an air purifier is determined by its clean air delivery rate (CADR), expressed as the product of the air flowrate and filter collection efficiency. A high CADR in a commercial air purifier is achieved using a pleated air filter with high filtration performance at a given air flowrate. However, obtaining this high filtration performance depends on the knowledge of the manufacturer, including the optimal pleating design, which remains uncertain to date. In this study, test pleated filters were prepared by folding a flat electrostatically-charged E12 filter medium to obtain different pleating geometries. The proper pleat geometry of the pleated filter, which has a minimum pressure drop at a fixed air flowrate, was dependent on the pleat length (P-L) and pleating ratio (alpha = pleat height/pleat width), wherein as the P-L increases, the alpha range required to achieve a minimum pressure drop similarly increases. Based on the filter quality factor (q(F)), the optimal pleat geometry of a pleated filter was between alpha values of 6-8, irrespective of the P-L. Although both P-L and alpha have certain influences on the q(F), alpha has a greater influence on the pleated filter with no dead zone.

키워드

collection efficiency; filter quality factor; pleated filter; pleating method; pleating ratio; pressure drop; PRESSURE-DROP; COLLECTION EFFICIENCY; AEROSOL-PARTICLES; PENETRATION; MEDIA; PERFORMANCE; DESIGNS
제목
Optimized pleat geometry at specific pleat height in pleated filters for air purification
저자
Kim, Ye-Lin; Kwon, Min-Seon; Lee, Myong-Hwa
DOI
10.1111/ina.13135
발행일
2022-10
유형
Article
저널명
Indoor Air
권
32
호
10