Embedded steel column-to-foundation connection for a modular structural system

  • Park, Keum-Sung
  • Moon, Jiho
  • Lee, Sang-Sup
  • Bae, Kyu-Woong
  • Roeder, Charles W.
Citations

WEB OF SCIENCE

110
Citations

SCOPUS

133

초록

Pre-made modular units permit rapid and economical construction and are increasingly used where repetitive units are required. The assembled building must behave as a single structure to effectively transfer the forces and moments developed by gravity and lateral loads. For this, individual modular units must be properly connected to each other. Therefore, evaluation of the behavior of connections used in modular construction is crucial. This study proposes an embedded steel column-to-foundation connection for modular structural systems and evaluates the behavior of the proposed connection. Experiments were performed to investigate the effect of the column embedment depth, the shape of the column end plate, and shear studs in the embedded region of the column on the connection behavior. Further, three dimensional nonlinear finite element analyses were conducted for each test specimen to demonstrate the in-depth behavior of the connection. Finally, a design equation for the proposed connection was proposed. (C) 2015 Elsevier Ltd. All rights reserved.

키워드

Steel column-to-foundation connectionEmbedded connectionConnection designBRACED FRAMESCONCRETEBUILDINGSTUBESMODEL
제목
Embedded steel column-to-foundation connection for a modular structural system
저자
Park, Keum-SungMoon, JihoLee, Sang-SupBae, Kyu-WoongRoeder, Charles W.
DOI
10.1016/j.engstruct.2015.11.034
발행일
2016-03-01
유형
Article
저널명
Engineering Structures
110
페이지
244 ~ 257