상세 보기
소음성 난청 환자에서 전기와우도의 변화
초록
Background and Objectives:Electrocochleography (ECoG) is a sensitive evoked-response test for evaluating changes in co-chlear function. We investigated the extratympanic ECoG in noise-induced temporary and permanent threshold shift to evaluate the usefulness of ECoG in the early detection and monitoring of noise-induced hearing loss (NIHL). Subjects and Method:(TTS). Pure-tone audiometry and ECoG were performed before (control-group), immediately after (TTS-group), and 24 hours after the exposure. And ECoG was measured in 27 ears with noise-induced permanent threshold shift (PTS-group). Results:The mean amplitude of SP (sumating potential) was greatest in the TTS-group. The largest increment in the SP/AP (action potential) ratio was also observed in the TTS-group. ± 0.11, 0.46± 0.18 and 0.37± 0.10, respectively. The PTS-group showed the smallest mean amplitude of AP. Conclusion:The results of this study suggest that SP, AP and the SP/AP ratio might be sensitive parameters reflecting the changes of cochlear function in NIHL.
키워드
- 제목
- 소음성 난청 환자에서 전기와우도의 변화
- 제목 (타언어)
- Electrocochleography in Noise-Induced Hearing Loss
- 저자
- 남의철
- 발행일
- 2004-04
- 유형
- Y
- 저널명
- 대한이비인후-두경부외과학회지
- 권
- 47
- 호
- 4
- 페이지
- 311 ~ 315