초록
This paper presents the results from cosmic ray tests performed in the framework of R&D effort on the forward Resistive Plate Chamber (RPC) for CMS. A double gap RPC of dimensions 50 × 50 cm2 with 2 mm gas gaps was tested. We report data on the use of tetrafluorethane-based gas mixture, with additions of water vapour and SF<inf>6</inf>. Efficiency, time resolution and cross-talk behaviour of the detector were investigated. © 2001 Elsevier Science B.V.
키워드
CMS; Double gap; RPC; SF6; Water vapour
- 제목
- Aspects of operational conditions of a double gap prototype RPC for the CMS/LHC experiment
- 저자
- Ahn, Sunghwan; Amirikas, Ramila; Bahk, Sangyull; Baik, K. M.; Gapienko, V. A.; Hong, Byungsik; Hong, Seongjong; Kim, Jae-yool; Kim, Yong-joo; Kim, Y. U.; Koo, D. G.; Lee, Kyong-sei; Lee, Seok-jae; Lim, Intaek; Nam, Soon-kwon; Pac, Myoung Youl; Park, Sungkeun; Rhee, June-tak; Seo, S. W.; Sim, Kwang-souk
- 발행일
- 2001
- 유형
- Article
- 권
- 465
- 호
- 2-3
- 페이지
- 447 ~ 454