초록
To evaluate the shear performance of the textile glass fiber and the sheet glass fiber reinforced glulam bolted connections, a tension type shear test was conducted. The average yield shear strength of the bolted connection of reinforced glulam was increased by 12% ? 31% compared to the non-reinforced glulam. It was confirmed that the shear performance of 5D end distance of the glass fiber reinforced glulam connection corresponds to that of 7D of the non-reinforced glulam connection proposed in building design requirements in various countries. Compared to the non-reinforced glulam, the average shear strength of textile glass fiber reinforced glulam was markedly increased. The non-reinforced glulam and the GFRP reinforced glulam underwent a momentary splitting fracture. However, the failure mode of textile glass fiber reinforced glulam showed a good ductility.
키워드
- 제목
- Shear performance of glass fiber reinforced glulam bolted connection
- 저자
- Kim, Keonho; Hong, Soonil
- 발행일
- 2015
- 유형
- Article
- 저널명
- 목재공학
- 권
- 43
- 호
- 5
- 페이지
- 661 ~ 671