골조-전단벽 구조에서 수평강성의 향상을 위한 기둥과 전단벽 단면적의 배분

Apportionment of Section Area of Column and Shear Wall for Improvement of Lateral Stiffness in Frame-Shear Wall Structures

초록

The research intended to search the optimal section area apportionment of columns and shear walls for improvement of lateral stiffness in frame-shear wall structure, using MIDAS-Gen. In this study, the main variables of analysis research were the section area ratios of column, the change of section area between the upper and lower columns and the change of thickness between the upper and lower shear walls. In order to find out the optimal section area apportionment of columns and shear walls for improvement of lateral stiffness in frame-shear wall structure, we examined the 30 stories reinforced concrete building. The results of this analysis study indicated that the section area ratios of column, the change of section area between the upper and lower columns, the change of thickness between the upper and lower shear walls had an impact upon the lateral stiffness in frame-shear wall structure. Moreover, it is showed that the research results can give help in obtaining the structural design data for finding out the optimal section area apportionment of columns and shear walls for improvement of lateral stiffness in frame-shear wall structure.

키워드

골조-전단벽 구조수평강성단면적 배분기둥전단벽Frame-Shear Wall StructureLateral StiffnessApportionment of Section AreaColumnShear Wall
제목
골조-전단벽 구조에서 수평강성의 향상을 위한 기둥과 전단벽 단면적의 배분
제목 (타언어)
Apportionment of Section Area of Column and Shear Wall for Improvement of Lateral Stiffness in Frame-Shear Wall Structures
저자
김형기
DOI
10.5659/JAIK_SC.2016.32.7.13
발행일
2016-07
유형
Y
저널명
대한건축학회논문집 구조계
32
7
페이지
13 ~ 22