상세 보기
초록
We present the detailed analysis of the time and charge signals of a prototype double gap resistive plate chamber for the endcap region of the compact muon solenoid detector at CERN LHC. We demonstrate that the operating high-voltage plateau can be extended at least up to 400 V with the present design. The simple avalanche multiplication model can reproduce the experimental charge spectra reasonably well at the beginning of the high-voltage plateau region. The effective Townsend coefficient is estimated in the avalanche mode operation. (C) 2004 Elsevier B.V. All rights reserved.
키워드
double gap RPC; CMS/LHC; avalanche mode; simulation; OPERATION; CMS; BAKELITE; RPC
- 제목
- Characteristics of a double gap resistive plate chamber for the endcap region of CMS/LHC: data vs. simulation in avalanche mode
- 저자
- Ahn, SH; Bahk, SY; Hong, B; Hong, SJ; Kang, DH; Kang, TI; Kim, KH; Kim, TJ; Kim, YJ; Kim, YU; Koo, DG; Lee, HW; Lee, KS; Lee, SJ; Lim, JK; Moon, DH; Nam, SK; Oh, JK; Park, S; Park, WJ; Rhee, JT; Ryu, MS; Sim, KS
- 발행일
- 2004-11-01
- 유형
- Article; Proceedings Paper
- 권
- 533
- 호
- 1-2
- 페이지
- 32 ~ 36