Optimal modified lateral shearing interferometer with axial range extension by using a dual optical plate

  • Seo, Kwang-Beom
  • Shin, Seung-Ho
Citations

WEB OF SCIENCE

3
Citations

SCOPUS

3

초록

We present a method to extend the axial range of digital holographic microscopy based on the optimal modified lateral shearing interferometer (MLSI). The proposed system can extend the axial range by using a dual optical plate. The interference pattern with two spatial wavelengths is generated by the plate with different thicknesses. These spatial wavelengths transfer a dual spatial frequency into the Fourier plane by using FFT. Two phases are extracted by a dual spatial frequency and combined to create a synthetic wavelength, which is applied to measure the micrometer-scale object without phase unwrapping. Also, the noise-reducing algorithm is used to reduce phase noise caused by the amplified noise of the synthetic wavelength. The experimental result confirms the feasibility of the optimal MLSI by using a dual optical plate. (C) 2020 Optical Society of America

키워드

DIGITAL HOLOGRAPHIC MICROSCOPYSPECKLE REDUCTIONRESOLUTION ENHANCEMENTSHAPE MEASUREMENTRECONSTRUCTION
제목
Optimal modified lateral shearing interferometer with axial range extension by using a dual optical plate
저자
Seo, Kwang-BeomShin, Seung-Ho
DOI
10.1364/AO.394757
발행일
2020-08-10
유형
Article
저널명
Applied Optics
59
23
페이지
6838 ~ 6847