메트로놈 도움 심폐소생술에서 메트로놈 설정속도에 따른 가슴압박 품질분석

Analysis of chest compression quality according to the metronome setting rate in metronome-assisted cardiopulmonary resuscitation

초록

Objective: The 2020 Cardiopulmonary Resuscitation (CPR) guidelines recommend the use of feedback devices during CPR training and do not limit their use in actual CPR. Although there have been various studies on metronome-assisted CPR that use a metronome as a feedback device, there are no research results to determine a specific metronome setting rate. We analyzed the quality of CPR and the effectiveness of the metronome feedback according to the metronome setting rate within the recommended chest compression rate range. Methods: Fifty healthcare providers who had received CPR training or had performed CPR in the previous 2 years participated, and all of them performed CPR at three rates (100/min, 110/min, and 120/min). The CPR was performed for 2 minutes with only chest compressions. The smartphone metronome (Metronome version 13.0 Android, KHTSXR, Seoul, Korea) application was used for the rate setting, and Resusci Anne QCPR Mk II (Laerdal Medical, Stavanger, Norway) was used to measure the CPR quality. The difference in the CPR quality according to the setting rate was analyzed. Results: There was no significant difference in the “average compression depth (mm),” “adequate compression depth ratio (%),” and “adequate release ratio (%)” at the three set rates. The “adequate compression rate ratio (%)” was 98.48 ±5.27% at 110/min, which was higher than that at 120/min or 100/min, and this was a statistically significant difference (P=0.000). There was no significant difference in the “adequate compression site ratio (%).” Conclusion: When performing metronome-assisted CPR, setting the rate to 110/min can more appropriately maintain the recommended chest compression rate range and can result in high-quality CPR.

키워드

Cardiopulmonary resuscitationFeedback deviceMetronome
제목
메트로놈 도움 심폐소생술에서 메트로놈 설정속도에 따른 가슴압박 품질분석
제목 (타언어)
Analysis of chest compression quality according to the metronome setting rate in metronome-assisted cardiopulmonary resuscitation
저자
채희진조준휘문중범신명철박윤수안웅찬옥택근
발행일
2024-02
유형
Y
저널명
대한응급의학회지
35
1
페이지
23 ~ 30