1초록
Hyperglycemia is an important risk factor for poor clinical outcomes in patients with acute myocardial infarction (AMI). The relative superiority of the long-term clinical outcomes of durable-polymer (DP)-based and biodegradable-polymer (BP)-based newer-generation drug-eluting stents (DESs) after successful percutaneous coronary intervention (PCI) in patients with AMI and prediabetes is not well established. We compared the clinical outcomes in such patients between DP-based and BP-based newer-generation DESs. A total of 4,377 patients with AMI and prediabetes were divided into the following two groups: the DP-DES group (n = 3,775; zotarolimus-eluting stents [ZES; n = 1,546] and everolimus-eluting stents [EES; n = 2,229]) and the BP-DES group (n = 602; biolimus-eluting stents [BES]). The primary endpoint was the occurrence of major adverse cardiac events (MACEs), defined as all-cause death, recurrent myocardial infarction (re-MI), or any repeat revascularization. The secondary endpoint was the occurrence of stent thrombosis (ST). The 2-year adjusted hazard ratio (aHR) of MACEs for ZES versus EES, ZES versus BES, EES versus BES, and ZES/EES versus BES (aHR: 1.125; 95% confidence interval [CI], 0.834-1.518; P = 0.440) were similar. The cumulative incidence of ST was also comparable between the DP-DES and BP-DES groups (aHR: 1.407; 95% CI, 0.476-4.158; P = 0.537). Moreover, the 2-year aHRs of all-cause death, CD, re-MI, target lesion revascularization (TLR), target vessel revascularization (TVR), and non-TVR were similar. Patients with AMI and prediabetes who received DP-DES or BP-DES during PCI showed comparable safety and efficacy during the 2-year follow-up period.
키워드
- 제목
- Comparison of Durable -Polymer-and Biodegradable-Polymer-Based Newer-Generation Drug-Eluting Stents in Patients with Acute Myocardial Infarction and Prediabetes After Successful Percutaneous Coronary Intervention
- 저자
- Kim, Yong Hoon; Her, Ae-Young; Jeong, Myung Ho; Kim, Byeong-Keuk; Hong, Sung-Jin; Kim, Seunghwan; Ahn, Chul-Min; Kim, Jung-Sun; Ko, Young-Guk; Choi, Donghoon; Hong, Myeong-Ki; Jang, Yangsoo
- 발행일
- 2020-07
- 유형
- Article
- 권
- 61
- 호
- 4
- 페이지
- 673 ~ 684