상세 보기
Impact of current smoking on 2-year clinical outcomes between durable-polymer-coated stents and biodegradable-polymer-coated stents in acute myocardial infarction after successful percutaneous coronary intervention: Data from the KAMIR
- Kim, Yong Hoon;
- Her, Ae-Young;
- Jeong, Myung Ho;
- Kim, Byeong-Keuk;
- Hong, Sung-Jin;
- 외 6명
WEB OF SCIENCE
9SCOPUS
11초록
Objective Data concerning the effect of current smoking on solely new-generation drug-eluting stents (DES) are limited. We investigated the impact of current smoking on 2-year clinical outcomes between durable-polymer (DP)-coated DES (zotarolimus-eluting [ZES] and everolimus eluting [EES]) and biodegradable-polymer (BP)-coated biolimus-eluting stent (BES) in acute myocardial infarction (AMI) patients after successful percutaneous coronary intervention (PCI). Methods Finally, a total of 8357 AMI patients with current smoking underwent successful PCI with new-generation DES (ZES, EES, and BES) were enrolled and divided into three groups as ZES (n = 3199), EES (n = 3987), and BES group (n = 1171). The primary endpoint was the occurrence of major adverse cardiac events (MACE) defined as all-cause death (cardiac death [CD] or non-cardiac death), recurrent AMI (re-MI), any revascularization (target lesion revascularization [TLR], target vessel revascularization [TVR], and non-TVR). The secondary endpoint was the incidence of definite or probable stent thrombosis (ST). Results The 2-year adjusted hazard ratio (HR) of MACE for ZES vs. EES (1.055; 95% confidence interval [CI], 0.843 +/- 1.321; p = 0.638), ZES vs. BES (HR, 0.885; 95% CI, 0.626 +/- 1.251; p = 0.488), EES vs. BES ( HR, 0.889; 95% CI, 0.633 +/- 1.250; p = 0.499), and ZES/EES vs. BES ( HR, 0.891; 95% CI, 0.648 +/- 1.126; p = 0.480) were similar. The occurrence of ST after adjustment were also comparable. In addition, the 2-year adjusted HR for all-cause death, CD, re-MI, TLR, TVR, and non-TVR were not different. Conclusions In this study, DP-DES and BP-DES showed comparable safety and efficacy during 2-year follow-up periods. Therefore, DP-DES or BP-DES are equally acceptable in AMI patients with current smoking undergoing PCI.
키워드
- 제목
- Impact of current smoking on 2-year clinical outcomes between durable-polymer-coated stents and biodegradable-polymer-coated stents in acute myocardial infarction after successful percutaneous coronary intervention: Data from the KAMIR
- 저자
- Kim, Yong Hoon; Her, Ae-Young; Jeong, Myung Ho; Kim, Byeong-Keuk; Hong, Sung-Jin; Shin, Dong-Ho; Kim, Jung-Sun; Ko, Young-Guk; Choi, Donghoon; Hong, Myeong-Ki; Jang, Yangsoo
- 발행일
- 2018-10-05
- 유형
- Article
- 저널명
- PLoS One
- 권
- 13
- 호
- 10
- 언어
- ENG
- 출판사
- PUBLIC LIBRARY SCIENCE
- 발행국가
- 미국
- ISSN
- E 1932-6203