Comparison Study of Fire Resistance According to Differences of Length of H-section Made of Submarine Structural Steels

  • Kwon, In-Kyu
Citations

WEB OF SCIENCE

0
Citations

SCOPUS

0

초록

Submarine structural steels, such as SM 400, SM 490, and SM 520, have the same structural properties and same grades as general structural steels, but those have better weldability than general structural steels. For that reason, their usage is increasing. However, their fire resistance is not well defined, except for individual fire resistance, such as column and beam. The fire resistance of H-section made of submarine structural steels can be applied with various column lengths. The fire resistance of them is not clear to engineers and residents. To determine the fire resistance, in this paper an analysis was conducted using their mechanical properties at high temperature and related theories with a standard fire curve. As the strength of submarine structural steels is increased, the structural stability showed a rapid decrease while the longer the length of column, the less structural stability of the column represented.

키워드

Fire resistanceHinge to hingeH-sectionStructural stabilityMechanical property at high temperature
제목
Comparison Study of Fire Resistance According to Differences of Length of H-section Made of Submarine Structural Steels
저자
Kwon, In-Kyu
DOI
10.4028/www.scientific.net/AMR.909.8
발행일
2014
유형
Proceedings Paper
저널명
Advanced Materials Research
909
페이지
8 ~ 11