Fast assessment of retrospective dosimetry using the SAAD-POSL method with core disc samples from building materials

  • Kim, M. J.
  • Lee, Y. J.
  • Lee, J. I.
  • Kim, J. L.
  • Hong, D. G.
Citations

WEB OF SCIENCE

2
Citations

SCOPUS

3

초록

To establish a fast assessment method of accidental dose, core disc samples were extracted from a heated red brick, roof tile, ceramic tile, and toilet porcelain, which are commonly used building materials. We examined the physical characteristics of pulsed optically stimulated luminescence (POSL) signals from these samples, and tested the reliability of the single aliquot additive dose (SAAD)-POSL method over a range of 7 Gy. In addition, when the SAAD-POSL method was applied, the minimum detectable dose (MDD) was as low as 0.01 Gy for the heated red brick, and the calculation time for an equivalent dose was as short as 2 h. This result indicates that the SAAD-POSL method is more effective as a fast assessment method of accidental dose than the SAR-OSL method. (C) 2014 Elsevier Ltd. All rights reserved.

키워드

Accidental doseBuilding materialPOSLSAAD methodCore disc sampleOPTICALLY STIMULATED LUMINESCENCEOSLQUARTZ
제목
Fast assessment of retrospective dosimetry using the SAAD-POSL method with core disc samples from building materials
저자
Kim, M. J.Lee, Y. J.Lee, J. I.Kim, J. L.Hong, D. G.
DOI
10.1016/j.radmeas.2014.04.013
발행일
2014-12
유형
Article; Proceedings Paper
저널명
Radiation Measurements
71