Chiral purity test of bevantolol by capillaryelectrophoresis and high performance liquid chromatography

  • Long, Pham Hai
  • Trung, Tran Quoc
  • Oh, Joung Won
  • Kim, Kyeong Ho
Citations

WEB OF SCIENCE

8
Citations

SCOPUS

4

초록

Two methods for the chiral purity determination of bevantolol were developed, namely capillary electrophoresis (CE) using carboxymethyl-beta-cyclodextrin (CM-beta-CD) as a chiral selector and high-perfornance liquid chromatography (HPLC) using a chiral stationary phase. In the HPLC method, the separation of bevantolol enantiomers was performed on a Chiralpak AD-H column by isocratic elution with n-hexane-ethanol-diethylamine (10:90:0.1, v/v/v) as mobile phase. In the CE method, bevantolol enantiomers were separated on an uncoated fused silica capillary with 50 mM amonium phosphate dibasic adjusted to a pH 6.5 with phosphoric acid containing 15 mM CM-beta-CD as running buffer. Validation data such as linearity, recovery, detection limit, and precision of the two methods are presented. The detection limits of S-(-)bevantolol were 0.1% and 0.05% for CE and HPLC method, respectively and R-(+)-bevantolol were 0.15% and 0.05% for CE and HPLC method, respectively. There was generally good agreement between the HPLC and CE results.

키워드

bevantololHPLCCEchiral separationoptical purityCAPILLARY-ELECTROPHORESISSEPARATIONENANTIOMERSASSAY
제목
Chiral purity test of bevantolol by capillaryelectrophoresis and high performance liquid chromatography
저자
Long, Pham HaiTrung, Tran QuocOh, Joung WonKim, Kyeong Ho
DOI
10.1007/BF02974083
발행일
2006-09
유형
Article
저널명
Archives of Pharmacal Research
29
9
페이지
808 ~ 813