Phase of acoustic impedance and performance of standing wave thermoacoustic coolers

Citations

WEB OF SCIENCE

5
Citations

SCOPUS

5

초록

Investigations on the relations between the phase angle of the acoustic impedance at the driver piston and the system performance of a standing wave thermoacoustic cooler were performed. The system performance measured at a fixed acoustic power showed that the coefficient of performance of the standing wave thermoacoustic cooler increases as the phase angle increases when the stack temperature span is relatively low. The results were consistent with the simulation results obtained from DELTAE, a computer code based on linear thermoacoustic theory. Analysis on the temperature profiles along the stack showed that the cooling efficiency (COP) of the system could be decreased or increased as the phase angle of the acoustic impedance at the driver piston changes depending on the stack temperature spans.

키워드

Coefficient of performancePhase angleStack temperature spanThermoacoustic cooler performanceELECTRODYNAMIC DRIVERS
제목
Phase of acoustic impedance and performance of standing wave thermoacoustic coolers
저자
Paek, InsuMongeau, LucBraun, James E.Kang, Shin You
DOI
10.1007/s12206-009-0351-2
발행일
2009-05
유형
Article
저널명
Journal of Mechanical Science and Technology
23
5
페이지
1476 ~ 1484