Comparative study of fire resistance performance for long span beams constructed with high strength submarine structural steels according to boundary conditions

  • Kwon, Ill-kyong
Citations

SCOPUS

0

초록

Requirements for building have been increased not only structural aspects but fire resistance. Therefore, a structural steel having higher strength has been developed and applied into building industry. Especially, a SM 520 and a SM 570 have good construction efficiencies in fabrication site and construction site, for these have a better welding performance and a higher strength than other structural steels. However, their fire resistance performance of them doesn't clear until now. In this study, to compare the fire resistance of long span beam built with SM 520 and SM 570, a fire engineering technique was used using mechanical properties at high temperatures and analytical methods. As the structural grades are going up, the performance of fire resistance is shown to be decreased. © 2017 Trans Tech Publications, Switzerland.

키워드

Boundary conditionsFire resistanceMechanical propertyStructural stability
제목
Comparative study of fire resistance performance for long span beams constructed with high strength submarine structural steels according to boundary conditions
저자
Kwon, Ill-kyong
DOI
10.4028/www.scientific.net/KEM.723.824
발행일
2017
유형
Conference paper
저널명
Key Engineering Materials
723 KEM
페이지