상세 보기
초록
The aim of this study was to validate an analytical method for the determination of platycoside E and platycodin D in Platycodon grandiflorum root extract. Specificity, linearity, precision, accuracy, limit of detection (LOD), and limit of quantification (LOQ) of platycoside E and platycodin D were measured by high performance liquid chromatography. Correlation coefficients of the calibration curve for platycoside E and platycodin D were 0.9999 and 0.9997, respectively. The inter-day and intra-day precision values of platycoside E and platycodin D ranged from 0.58 to 3.59% and from 0.4 to 4.77%, respectively. The inter-day nd intra-day accuracies were 94.02 to 115.73% and 94.11 to 122.82%, respectively. The LOD for platycoside E and platycodin D was 0.22 μg/mL and 0.31 μg/mL, respectively. The results validated the analytical determination of platycoside E and platycodin D in Platycodon grandiflorum root extract.
키워드
- 제목
- 발효된 도라지 추출물의 지표성분(Platycoside E 및 Platycodin D) 분석법 검증
- 제목 (타언어)
- Validation of Analytical Method for Platycoside E and Platycodin D in Fermented Platycodon grandiflorum Root Extract
- 저자
- 최예은; 최선일; 한웅호; 문효; 장길웅; 권희연; 박병우; 김정진; 이옥환
- 발행일
- 2020-07
- 유형
- Y
- 저널명
- 농업생명환경연구
- 권
- 32
- 호
- 2
- 페이지
- 116 ~ 126
- 언어
- KOR
- 출판사
- 강원대학교 농업생명과학연구원
- 발행국가
- 대한민국
- 분량
- 11 페이지
- ISSN
- P 2233-8322