Effect of micro air void system on the permeability of latex-modified concretes with ordinary Portland and very early strength cements

Citations

WEB OF SCIENCE

1
Citations

SCOPUS

2

초록

This study focused on the impact of the micro air void system on the chloride permeability of latex-modified concretes with ordinary Portland and very early strength cements. The micro air void system was analyzed with the image analysis method. The results of this study will help field engineers and researchers gain a better understanding of the chloride permeability characteristics of latex-modified concretes. The results show that the latex-modified concretes made with both Portland and very early strength cements have more micro air voids, ranging 50 to 500 pin, than ordinary concretes. These small air voids decrease the spacing factor, which is defined as half the average distance that unstable water must travel to reach an escape boundary. The specific surface ranges from 8 to 27 mm(-1) and the spacing factor ranges from 275 to 602 pm for ordinary Portland and very early strength cement concretes without and with latex modification. The specific Surface tends to decrease as the spacing factor increases. The spacing factors of concretes tend to decrease with latex modification and with very early strength cement. It seems clear that the use of polymer latex in concrete can significantly lower the value of the air void spacing factor by entraining a large number of micro air voids (below 100 mu m in diameter).

키워드

latex-modified concrete (LMC)micro air void systemchloride permeabilityimage analysis
제목
Effect of micro air void system on the permeability of latex-modified concretes with ordinary Portland and very early strength cements
저자
Yun, K. K.Kim, D. H.Kim, K. J.
DOI
10.1139/L07-011
발행일
2007-08
유형
Article
저널명
Canadian Journal of Civil Engineering
34
8
페이지
895 ~ 901