상세 보기
Randomized Comparison of Everolimus-Eluting Stent Versus Sirolimus-Eluting Stent Implantation for De Novo Coronary Artery Disease in Patients With Diabetes Mellitus (ESSENCE-DIABETES) Results From the ESSENCE-DIABETES Trial
- Kim, Won-Jang;
- Lee, Seung-Whan;
- Park, Seong-Wook;
- Kim, Young-Hak;
- Yun, Sung-Cheol;
- ... Lee, Bong-Ki;
- 외 29명
WEB OF SCIENCE
98SCOPUS
110초록
Background-Drug-eluting stents significantly improved angiographic and clinical outcomes compared with bare metal stents in diabetic patients. However, a comparison of everolimus-eluting stents and sirolimus-eluting stents in diabetic patients has not been evaluated. Therefore we compared effectiveness of everolimus-eluting stents and sirolimus-eluting stents in patients with diabetes mellitus. Methods and Results-This prospective, multicenter, randomized study compared everolimus-eluting stent (n = 149) and sirolimus-eluting stent (n = 151) implantation in diabetic patients. The primary end point was noninferiority of angiographic in-segment late loss at 8 months. Clinical events were also monitored for at least 12 months. Everolimus-eluting stents were noninferior to sirolimus-eluting stents for 8-month in-segment late loss (0.23 +/- 0.27 versus 0.37 +/- 0.52 mm; difference, -0.13 mm; 95% confidence interval, -0.25 to -0.02; upper 1-sided 95% confidence interval, -0.04; P<0.001 for noninferiority), with reductions in in-stent restenosis (0% versus 4.7%; P=0.029) and in-segment restenosis (0.9% versus 6.5%; P=0.035). However, in-stent late loss (0.11 +/- 0.26 versus 0.20 +/- 0.49 mm; P=0.114) was not statistically different between the 2 groups. At 12 months, ischemia-driven target lesion revascularization (0.7% versus 2.6%; P=0.317), death (1.3% versus 3.3%; P=0.448), and myocardial infarction (0% versus 1.3%; P=0.498) were not statistically different between the 2 groups. Major adverse cardiac events, including death, myocardial infarction, and ischemia-driven target lesion revascularization (2.0% versus 5.3%; P=0.218), were also not statistically different between the 2 groups. Conclusions-Everolimus-eluting stents were noninferior to sirolimus-eluting stents in reducing in-segment late loss and reduced angiographic restenosis at 8 months in patients with diabetes mellitus and coronary artery disease.
키워드
- 제목
- Randomized Comparison of Everolimus-Eluting Stent Versus Sirolimus-Eluting Stent Implantation for De Novo Coronary Artery Disease in Patients With Diabetes Mellitus (ESSENCE-DIABETES) Results From the ESSENCE-DIABETES Trial
- 저자
- Kim, Won-Jang; Lee, Seung-Whan; Park, Seong-Wook; Kim, Young-Hak; Yun, Sung-Cheol; Lee, Jong-Young; Park, Duk-Woo; Kang, Soo-Jin; Lee, Cheol Whan; Lee, Jae-Hwan; Choi, Si Wan; Seong, In-Whan; Lee, Bong-Ki; Lee, Nae-Hee; Cho, Yoon Haeng; Shin, Won-Yong; Lee, Seung-Jin; Lee, Se-Whan; Hyon, Min-Su; Bang, Duk-Won; Park, Woo-Jung; Kim, Hyun-Sook; Chae, Jei Keon; Lee, Keun; Park, Hoon-Ki; Park, Chang-Bum; Lee, Sang-Gon; Kim, Min-Kyu; Park, Kyoung-Ha; Choi, Young-Jin; Cheong, Sang-Sig; Yang, Tae-Hyun; Jang, Jae-Sik; Her, Sung Ho; Park, Seung-Jung
- 발행일
- 2011-08
- 유형
- Article
- 저널명
- Circulation
- 권
- 124
- 호
- 8
- 페이지
- 886 ~ U84