Purpose: This study compared the angiographic outcomes of paclitaxel-coated balloon (PCB) versus plain old balloon angioplasty (POBA) treatment for de novo coronary artery lesions. At present, there is no available data comparing the efficacy of PCB versus POBA for the treatment of de novo coronary lesions. Materials and Methods: This multicenter retrospective observational study enrolled patients with de novo coronary lesions with a reference vessel diameter between 2.5 mm and 3.0 mm and lesion length <= 24 mm who were successfully treated with PCB or POBA. Angiographic measurements and quantitative coronary analysis were performed before and after the procedure, and at 9 months follow-up. Results: A total of 72 patients (49 receiving PCB and 23 receiving POBA) were enrolled in this study. Late luminal loss was -0.12 +/- 0.30 mm in the PCB group and 0.25 +/- 0.50 mm in the POBA group (p<0.001). There was a higher percentage of binary restenosis (diameter stenosis >= 50%) in POBA, compared to PCB (30.4%, n=7 vs. 4.1%, n=2, p<0.001). Target vessel revascularization was higher in the POBA group (13.0%, n=3 vs. 0%, p=0.033). Conclusion: PCB treatment of de novo coronary lesions showed better 9-month angiographic outcomes than POBA treatment

키워드

Paclitaxel-coated balloonde novo coronary lesionplain old balloon angioplastyrestenosisrevascularizationARTERY-DISEASEELASTIC RECOILRESTENOSISINTERVENTIONIMPLANTATIONDELIVERYSTENTS
제목
Comparison of Paclitaxel-Coated Balloon Treatment and Plain Old Balloon Angioplasty for De Novo Coronary Lesions
저자
Her, Ae-YoungAnn, Soe HeeSingh, Gillian BalbirKim, Yong HoonYoo, Sang-YongGarg, ScotKoo, Bon-KwonShin, Eun-Seok
DOI
10.3349/ymj.2016.57.2.337
발행일
2016-03-01
유형
Article
저널명
Yonsei Medical Journal
57
2
페이지
337 ~ 341