상세 보기
9층 공학목재 사무소 건물의 성능기반 내진설계
- 추유림;
- 김태완;
- 김승래
초록
One of engineered woods, glued laminated timber (GLT), can provide a constant level of performance and desired strength even if the quality of wood is low. Due to this fact, there is a growing interest in GLT using domestic species and related research has been carried out continuously. In addition, GLT is popularly being applied to the long-span or high-rise structures overseas. However, KBC 2016 does not allow the engineered woods to be used for middle and high-rise buildings by limiting height. Therefore, a proper design procedure and rationale should be clearly presented by the help of performance-based seismic design. With this background, the goal of this study is to establish a specific procedure for design of a 9-story building with RC shear walls and GLT frames according to the performance-based design of KBC 2016. The performance objectives were set according to KBC and the acceptance criteria for each goal were defined. The RC shear walls and GLT frames were designed by concrete and wood structure requirements, respectively. Analytical models were developed to reflect their nonlinear features, and both nonlinear static and dynamic analyses were conducted. Performance evaluation results showed that the shear walls have insufficient shear strength, so they were re-designed. Consequently, it has been confirmed that GLT frames can be applied to a 9-story office building with the assistance of RC shear walls and performance-based seismic design.
키워드
- 제목
- 9층 공학목재 사무소 건물의 성능기반 내진설계
- 제목 (타언어)
- Performance-based Seismic Design of 9-Story Engineered Wood Office Building
- 저자
- 추유림; 김태완; 김승래
- 발행일
- 2018-05
- 유형
- Y
- 저널명
- 한국지진공학회논문집
- 권
- 22
- 호
- 4
- 페이지
- 225 ~ 233
- 언어
- KOR
- 출판사
- 한국지진공학회
- 발행국가
- 대한민국
- 분량
- 9 페이지
- ISSN
- E 2234-1099
P 1226-525X