상세 보기
Feasibility of improved motion-sensitized driven-equilibrium (iMSDE) prepared 3D T1-weighted imaging in the diagnosis of vertebrobasilar artery dissection
- Choi, Jin Wook;
- Han, Miran;
- Hong, Ji Man;
- Lee, Jin Soo;
- Kim, Sun Yong;
- ... Kim, Sam Soo
WEB OF SCIENCE
17SCOPUS
18초록
Background and purpose. - This study was to evaluate the diagnostic value of improved motion-sensitized driven-equilibrium (iMSDE)-prepared 3D T1-weighted magnetic resonance imaging (MRI) (iMSDE-3DMRI) in intracranial vertebrobasilary dissection (VBD) and to compare iMSDE-3DMRI images with those obtained using 2D high-resolution (HR) MRI with respect to their diagnostic performance in VBD. Materials and methods. - We retrospectively reviewed 105 lesions from 102 patients who underwent multimodal imaging and contrast-enhanced iMSDE-3DMRI (CE-iMSDE-3DMRI). The 2D-HRMRI protocol comprised four axial HR images. The CE-iMSDE-3DMRI images were reformatted in the axial, coronal, and sagittal planes. The 2D-HRMRI-based diagnosis was compared with the final diagnosis. The 2D-HRMRI and CE-iMSDE-3DMRI images were examined independently for the diagnosis performance of dissection. Results. - VBD was confirmed in 66 lesions in 63 patients; 17 patients had confirmed atherosclerosis, and 22 had no lesions in the vertebrobasilar artery. Diagnostic performances of 2D-HRMRI (AUC, 0.839 +/- 0.04; sensitivity, 94.0; specificity, 79.5; diagnostic accuracy, 88.6) CE-iMSDE-3DMRI (AUC, 0.847 +/- 0.04; sensitivity, 84.8; specificity, 84.6; diagnostic accuracy, 84.7) and 2D-HRMRI + CE-iMSDE-3DMRI (AUC, 0.893 +/- 0.03; sensitivity, 97.0; specificity, 85.0; diagnostic accuracy, 92.5) were good. Comparisons of the diagnostic performance of 2D-HRMRI andCE-iMSDE-3DMRI showed that combined interpretation of 2D-HRMRI and iMSDE-3DMRI yields a significantly higher diagnostic performance than that of 2D-HRMRI (P= 0.042). Conclusions. - CE-iMSDE-3DMRI showed good diagnostic performance for the diagnosis of intracranial VBD. These results suggest that CE-iMSDE-3DMRI can be used in combination with 2D-HRMRI for the diagnosis of intracranial VBD. (C) 2017 Elsevier Masson SAS. All rights reserved.
키워드
- 제목
- Feasibility of improved motion-sensitized driven-equilibrium (iMSDE) prepared 3D T1-weighted imaging in the diagnosis of vertebrobasilar artery dissection
- 저자
- Choi, Jin Wook; Han, Miran; Hong, Ji Man; Lee, Jin Soo; Kim, Sun Yong; Kim, Sam Soo
- 발행일
- 2018-05
- 유형
- Article
- 권
- 45
- 호
- 3
- 페이지
- 186 ~ 191