상세 보기
초록
Instead of direct driving like BLDC, the induction principle is adopted as a driving one for planar stage. The stage composed of four linear induction motors put in square type is activated by two-axial forces; low-frequency attractive force and thrust force of the linear induction motors. Here, the modified vector control whose new inputs are q-axis current and dc current biased to three phase current instead of d-axis current or flux current is applied extensively to overall motion of the stage. For the developed system, the precision step test and the constant velocity test are tried to guarantee its feasibility for TFT-LCD pattern inspection. However, to exclude a discontinuity due to phase shift and minimize a force ripple synchronized with the command frequency, the initial system is revised to the antagonistic structure over the full degree of freedom. Concretely describing, the porous air bearings guide an air-gapping of the stage up and down and a pair of liner induction motors instead of single motor are activated in the opposite direction each other. The performances of the above systems are compared from trapezoid tracking test and sinusoidal test.
키워드
- 제목
- 인덕션 방식을 이용한 평면 스테이지의 동특성 개선
- 제목 (타언어)
- Improvement of Dynamic Characteristic of Large-Areal Planar Stage Using Induction Principle
- 저자
- 정광석; 박준규; 김효준
- 발행일
- 2009-07
- 유형
- Y
- 저널명
- 제어.로봇.시스템학회 논문지
- 권
- 15
- 호
- 7
- 페이지
- 675 ~ 682